ILT5000 Lab Radiometer for Measuring Low Intensity Narrowband Sources at 254 nm
![ILT5000 Research germicidal measurement system](/sites/default/files/styles/large/public/2019-04/ilt5000_w_tablet_gray_3.png?itok=kD02-g4K)
ILT5000,SED240/W
Research UV-C Radiometer Germicidal Measurement System
- 10+ Decade Dynamic Range of Optical Analysis
- Pico-ammeter: 10fA to 1mA (calibrated from 100fA - 1mA)
- Wireless Communication, Built-in
- User controlled or Auto: Range, Zero/Dark, Sample Rate
- 4-20 mA Output
- 15 pin D Sub and SMA sensor/input ports
- “Set it & Forget It” Remote Data Logging
- Power: USB or Built-in Re-Chargeable Battery Pack
- Multi-System Simultaneous Continuous Monitoring
- Includes DataLight II Software and Labview Sample Code
- NIST-Traceable/ISO/IEC 17025:2017 Accredited Calibration
- Sample Rate Up to 100 Hz, Programmable
- Made in the USA
- Custom & OEM Inquiries Welcome
< Back to Germicidal Light Measurement Table
![SED240W Response Curve](/sites/default/files/sed240w_0.jpg)
LOW INTENSITY UVC GERMICIDAL DETECTOR
Configured to measure low intensity, low-pressure mercury lamps for 254 nm output (see sensor spectral response curve) as well as UV LED's used for sterilization / germicidal applications.
Measurement Range: 1.00e-9 to 5.00e-4 Watts/cm2
UV Actinic Hazard Spectral Range: 185 – 320 nm, calibration wavelength at 254 nm (other calibration wavelengths are available)
Dimensions: 60 mm x 42 mm diameter
Order part numbers: ILT5000*, SED240/W (detector)
* Software Included / Table PD Sold Separately
Note: SED240/W detector also works with the ILT2500 Flash Meter
Applications:
![SED240 Cosine Response Graph](/sites/default/files/sed240_cosine_response_0.png)
This detector has a peak spectral response at 254 nm and is designed to measure low-intensity, narrowband sources with output in 254 nm range. Since low-pressure mercury lamps produce better than 95% of their energy at 254 nm, no bandbass filters are needed. When used with UVC LED's, calibration at peak wavelengths are also available.
![SED SEL 240W Detector](/sites/default/files/styles/medium/public/sed-sel-240-w2.jpg?itok=jUjW_WQX)
Click for larger image
Filters and input optics are removable and may be ordered separately from the detector assembly to allow filter and input optic swapping.
Note: For simultaneous multi-sensor data logging, ILT also offers the ILT6000 Rack-Mount Radiometer System with the same specifications as the ILT5000 in a 2-10 unit,rack mountable housing.
![ILT6000 rack mount radiometer](/sites/default/files/styles/large/public/ilt6000_0.jpg?itok=FGXQ_eal)
![ILT6000 board](/sites/default/files/styles/medium/public/ilt-a6000-0184_web_0.jpg?itok=2uI0xb1o)
For the latest meter specifications, data sheet, installation guide, tech notes and software, visit the ILT5000 page here.