ILT570-VIS Visible Light Spectroradiometers

ILT570-VIS Visible Light Spectroradiometers
Features:
- For visible light measurement applications
- Spectral range from 400 nm - 800 nm
- Easy to use
- User-friendly SpectriLight software included
- Reliable and trustworthy results
- Choose from the most comprehensive selection of preconfigured light measurement kits
from the UV to NIR spectral range. - Fully characterized and calibrated kits with ISO 17025-certified processes.
- Global Recalibration Centers in North America, Europe, and China.
- Ideal for product development, inspection, quality control, performance validation,
and production
From Development to Production, Measure with Confidence
The ILT570VIS Mini Spectroradiometric Measurement Systems are ideal for testing and measurement of visible light sources. We offer seven options for measuring light sources from 350 nm to 800 nm. Each Spectroradiometer System includes our visible mini spectrometer and optical fiber, an optical measurement head for spectral irradiance, spectral radiance, or spectral flux, a stand, SpectrILight III control software & DLLs, and a carry and storage case.
These Spectroradiometer Systems have been fully characterized and are calibrated for their spectroradiometric response following ISO 17025-certified processes, and supported by global recalibration centers in North America, Europe, and China. Ideal for product development, inspection, and production, ILT’s Spectroradiometric Measurement Systems offer the precision and reliability your project demands.
Spectroradiometers for measuring:
- Spectral Irradiance, Irradiance, Illuminance and Color
- Spectral Radiance, Radiance, Luminance and Color
- Spectral Flux, Optical Power, Lumens and Color
Ideal for:
- Product Development
- Inspection
- Quality Control
- Performance Validation
- Production
Choose from the below, pre-configured kits, for an out-of-box spectral irradiance measurement solution. Click on the below links for full system specifications and ordering information.
- ILT570VIS-RAA4 - Right angle adapter/diffuser head with 11 mm aperture and mini-integrating sphere for measuring spectral irradiance, total irradiance, and spectral characteristics of light sources
- ILT570VIS-W/A2 - Silica chip head with SMA adaptor for measuring spectral and total irradiance, illuminance, color parameters, and spectral characteristics of light sources.
- ILT570VIS-W5E - Miniature cosine correcting diffuser with SMA905 fiber adaptor for measuring spectral and total irradiance, color parameters, and spectral characteristics of light sources
- ILT570VIS-R2 - Optical Head with an average field of view of 2 degrees for measuring spectral and total radiance, luminance, color parameters, and spectral characteristics of extended light sources
- ILT570VIS-R3 - Small Spot, 500 mm fixed distance Optical Head for measuring spectral and total radiance, luminance, color parameters, and spectral characteristics of extended light sources
- ILT570VIS-INT50 - 5 cm (2”) integrating sphere for measuring forward and total spectral flux, power in watts, and spectral characteristics.
- ILT570VIS-INT150 - 15 cm (6”) integrating sphere for measuring forward and total spectral flux, power in watts, and spectral characteristics.
Versatile
The ILT570-VIS can be paired with additional input optics. Each input optic requires its own unique calibrations, however multiple calibrations can be performed on a single spectrometer, allowing measurements of total flux (W, lm), irradiance (W/cm2), radiance (W/sr/cm2), luminance (cd/m2), and illuminance (lux) with just one system.
Spectroradiometer Accessories

Click on image to go to Spectroradiometer Accessories page for additional, optional accessories. Note: Not all accessories are compatible with this spectroradiometer.
SpectrILight III Software
SpectrILight™ III is a LabView™ based software package for Windows that allows you to acquire spectral and color data. Analysis of the data is now calculated instantly within the same program - no exporting required!
SpectrILight™ III includes calculations for metamerism, and 2 and 10 degree observer. The overlay feature allows the user to compare the base reading to current readings. Wavelength range, integration time, scan average and other controls can be easily set through pop up windows, menus and tool bars. Absolute Irradiance and chromaticity are calculated instantly.


Specifications | |||||||
---|---|---|---|---|---|---|---|
Model | ILT570VIS-RAA4 | ILT570VIS-W/A2 | ILT570VIS-W5E | ILT570VIS-R2 | ILT570VIS-R3 | ILT570VIS-INT50 | ILT570VIS-INT150 |
Type | VIS Spectral Irradiance | VIS Spectral Irradiance | VIS Spectral Irradiance | VIS Spectral Radiance | VIS Spectral Radiance | VIS Spectral Flux | VIS Spectral Flux |
Spectral Range of Spectrometer | 350 nm to 810 nm | ||||||
Spectral Range of Calibration | 350 nm to 800 nm | 350 nm to 800 nm | 350 nm to 800 nm | 350 nm to 800 nm | 350 nm to 800 nm | 350 nm to 800 nm | 350 nm to 800 nm |
Radiometric Dynamic Range (400-800 nm) | 1.01 E-02 to 2.7 E+02 W/cm2 | 3.82 E-02 to 1.03 E+03 W/cm2 | 1.78 E-02 to 4.79 E+02 W/cm2 | 1.41 E-03 to 3.77 E+01 W/cm2/sr | 2.71 E-02 to 7.28 E+02 W/cm2/sr | 6.65 E-06 to 1.78 E-01 W | 6.02 E-05 to 1.62 W |
Luminous Flux Range for 3200 QTH | -- | -- | -- | -- | -- | 0.003 to 47 lumens | 0.02 to 400 lumens |
Illuminance Range | 25 to 150K lux | 100 to 600K lux | 50 to 250K lux | -- | -- | -- | -- |
Luminance Range | -- | -- | -- | 1.0 to 2.0 E+04 cd/m2 | 2.0 to 2.0 E+04 cd/m2 | ||
Integration Time Range | 3.8 ms to 8 sec | ||||||
Spectral Resolution | 2.2 nm | ||||||
Wavelength Accuracy | 0.9 nm | ||||||
Stray Light Rejection | 2 AU | ||||||
Fiber Length | 1 m | ||||||
Fiber Connections | SMA-905 | ||||||
Optical Heads | RAA4 | W/A2 | W5E | R2 | R3 | INT50 | INT150 |
Input Configuration | Right Angle | Parallel | Parallel | Radiance/Luminance Optic w/2 Deg FOV | Radiance/Luminance Optic w/3 Deg FOV | Sphere Entrance Port | Sphere Entrance Port |
Reference Plane | Front Surface | Front Surface | Front Surface | -- | -- | Sphere Entrance Port | Sphere Entrance Port |
Active Sensor Area |
0.27 inch |
0.598 inch |
0.157 inch (4 mm) dia. |
0.383 inch (9.7 mm) dia |
0.59 inch (15.0 mm) dia. |
.28 inch (7mm) input port |
1.5 inch (38mm) input port |
Optical Head Dimensions | .061inch (1.54cm) dia. by 0.44 inch (1.12 cm) tall |
1.65 inch (4.19 cm dia. by 1.29 inch (3.28 cm) tall | 1.25 inch (0.64 cm) dia. by 0.79 inch (2.0 cm) long | 1.54 inch (4.19 cm) dia. by 1.46 inch (3.70 cm) tall | 1.98 inch (4.27 cm) base dia., 1.20 inch (3.05 cm) lens dia., by 2.40 (6.10 cm) tall | 2 inch (5cm) dia. integrating sphere with 0.27 inch (7mm) entrance port and 0.5 inch (1.27 cm) near cosine fiber port | 6 inch (15.24 cm) integrating sphere with 3 ports; 1.5 inch (3.8 cm) entrance port, 0.5 inch (1.24 cm) near cosine fiber port, and 1 inch (2.54cm) north entrance port with port plug |
Spectrometer Dimensions HxWxL | 1.65 inch (42 mm) x 1.57 inch (40 mm) x 1.06 inch (27 mm) | ||||||
Spectrometer Weight | 70 g | ||||||
Sphere Coating | -- | -- | -- | -- | -- | Spectraflect* | Spectraflect* |
Mounting | 1/4-20 mounting thread with tripod | 1/4-20 mounting thread with tripod | 1/4-20 mounting thread with tripod | 1/4-20 mounting thread with tripod | 1/4-20 mounting thread with tripod | 1/4-20 mounting thread with tripod | 1/4-20 boss, 4 inch (10 cm) post holder, and 6 in x 6 in (15cm x 15cm) base |
Calibration | Spectral Irradiance Response | Spectral Irradiance Response | Spectral Irradiance Response | Spectral Radiance Response | Spectral Radiance Response | Spectral Flux Response | Spectral Flux Response |
Storage and Carrying Case | Included | Included | Included | Included | Included | Included | Included |
Software** | SpectriLight III | SpectriLight III | SpectriLight III | SpectriLight III | SpectriLight III | SpectriLight III | SpectriLight III |
*Spectraflect is a registered trademark of Labsphere
**Computer Specifications
- A CPU or laptop with 1GHz processor, 1GB of RAM, 256GB hard drive, and a screen resolution of 1024 x 768
- Operating system: Windows 11 or later
- Microsoft .Net Framework 4.5 or later needs to be installed and enabled