ILT5000 Specs
Research Germicidal Measurement System
- 10+ Decade Dynamic Range of Optical Analysis
- Pico-ammeter: 10fA to 1mA (calibrated from 100fA - 1mA)
- Wireless Communication, Built-in
- User controlled or Auto: Range, Zero/Dark, Sample Rate
- 4-20 mA Output
- 15 pin D Sub and SMA sensor/input ports
- “Set it & Forget It” Remote Data Logging
- Power: USB or Built-in Re-Chargeable Battery Pack
- Multi-System Simultaneous Continuous Monitoring
- Includes DataLight II Software and Labview Sample Code
- NIST-Traceable/ISO17025 Accredited Calibration
- Sample Rate Up to 100 Hz, Programmable
- Made in the USA
- Custom & OEM Inquiries Welcome
ILT1700 Specs
Bench-Top Research Germicidal Light Measurement System
- Industry Standard Research Radiometer
- Direct Reading in Scientific Notation
- Best Price Performance
- Unsurpassed Reliability for 15 years
- Dynamic Auto Ranging – no lost samples in pulsed
applications - 10 Decade Dynamic Range
- 0.1 Percent Linearity
- 40 Decade Integration Range
- Light Integration up to 18 Years
- 10 Calibration Factors in Memory
- Made in the USA
- Custom & OEM Inquiries Welcome!
LOW INTENSITY, LOW PRESSURE MERCURY DETECTOR
![SED240W Response Curve](/sites/default/files/sed240w.jpg)
Configured to measure low intensity, low-pressure mercury lamps only.
Measurement Range: 1.00e-9 to 5.00e-4 Watts/cm2
UV Actinic Hazard Spectral Range: 185 – 320 nm, calibration wavelength at 254 nm
Dimensions: 60 mm x 42 mm diameter
Order part numbers: ILT1700 (meter), SED240/W (detector)
Applications: This detector has a peak spectral response at 254 nm and is designed to measure low-intensity, low-pressure mercury sources only. Since low-pressure mercury lamps produce better than 95% of their energy at 254 nm, they are easily measured by this detector without additional filtration.
![SED SEL 240W Detector](/sites/default/files/styles/medium/public/sed-sel-240-w.jpg?itok=Xt-0rEjX)
![W Cosign](/sites/default/files/w_cosign.jpg)
For the latest meter specifications, data sheet, installation guide, tech notes and software, visit the ILT5000 page here.