ILT5000 PMT-Based Low Light Scotopic Lux-Illuminance Measurement System
ILT5000 Radiometer, SPM068-1/ZPM/W Scotopic Detector
PMT-Based Low Light Scotopic Lux-Illuminance Measurement System
- Over 10 Decades 100 fA - 1 mA Measurement Range
(1 n/Wcm2 to 10 W/cm2) - Auto-Ranging
- Built-in Wi-Fi
- Operating Temperature: -40 to 85° C
(Calibrated Irradiance: 0-50° C) - USB: USB2, Including Power, for Single and Multiple Systems
- USB Current Draw: 500 mA max., 250 mA typical
- Size: 1-3/5" H x 5" W x 7" L
- Input Connector: D-Sub and SMA
- CE Certified: No rf noise
- Calibration: NIST Traceable/ISO/IEC 17025:2017 Accredited
- DataLight III for Mac OS and Windows 7, 8 & 10
- Made in the USA
- Custom & OEM Inquiries Welcome
With the ILT5000, it's all about supplying fast, reliable data to your computer for analysis. Our extensive DataLight III light measurement software is available for Windows 7, 8 & 10 and MAC OS X.
The Meters App allows transmission of measurement data via USB or wirelessly. Additional features include single/multi-system graphical display, single reading capture and data recording, auto ranging, zero, hold and integrate.
SPM068-1/ZPM/W Scotopic Illuminance PMT detector is designed for low light level illuminance measurements.
Includes ZPM Scotopic filter, which matches the wavelength responsibly of the human eye under dark adapted conditions and a W cosine correcting diffuser. The PMT includes a range switch on the connector to increase the gain by a factor of two.
Additional calibration is recommended to assure accuracy in High mode. QNDS3 neutral density filter (X1000) can be added to prevent saturation and to protect the PMT.
Dynamic Range: 1e-6 to 7e-1 fc (low mode) or 1e-8 to 7e-3 fc (high mode)
(Note: Ranges are based on conservative averages. Take care not to approach noted range on the sensor calibration certificate to prevent irreparable damage to the PMT from saturation.)
Measurement Range: 400-700 nm
Dimensions: 112 mm x 42 mm dia.
Ordering part#(s): ILT5000, SPM068-1/ZPM/W. (Add ZIS calibration for High Gain and QNDS3 Neutral Density Filter for protection as needed.)
Filters and input optics are removable and may be ordered separately from the detector assembly to allow filter and input optic swapping.
DataLight III Software
With the ILT5000 its all about supplying fast, reliable data to your computer for analysis. Our extensive DataLight III light measurement software is available for Windows PC, Tablet and MAC computers. DataLight III includes our set it and forget it remote internal data storage app., and an improved All-in-One meters app for control and transmission of data using a mini USB cable or wireless data transmission.
For the latest meter specifications, data sheet, installation guide, tech notes and software, visit the ILT5000 page here