ILT960VIS-RAA4 Spectroradiometer for Visible Light Applications
ILT960VIS-RAA4 Spectroradiometer for Visible Light Applications
Features
- Compact, portable design
- VIS, UV, and full range UV-NIR calibrations available
- Extensive software package included
- Calculates both Radiometric and Photometric values
- Broad light level range is adjustable
- Linear and repeatable measurements
- QTH/NIST Traceable, ISO/IEC 17025:2017 Accredited Calibration
- Includes dual source calibration for 200-850 nm
The ILT960- VIS System
The ILT960VIS-RAA4 is a complete light measurement system including a compact portable mini spectrometer, one meter fiber optic light quide, miniature right angle cosine correcting diffuser, tripod, carrying case, calibration and certification. The system is used to measure both the lights amplitude and wavelength and provides absolute spectral irradiance in W/m2/nm.
ILT's SpectrILight III software package is FREE with the purchase of an ILT spectrometer system. DLL’s and expanded range of calibration is available for an extra fee.
Watch a demo of the ILT960 spectroradiometer with SpectrILight III software
SpectrILight III Software
SpectrILight™ III is a LabView™ based software package for Windows that allows you to acquire spectral and color data. Analysis of the data is now calculated instantly within the same program - no exporting required!
SpectrILight™ III includes calculations for metamerism, and 2 and 10 degree observer. The overlay feature allows the user to compare the base reading to current readings. Wavelength range, integration time, scan average and other controls can be easily set through pop up windows, menus and tool bars. Absolute irradiance and chromaticity are calculated instantly.
Specifications | |
---|---|
Model | ILT960-VIS |
Detector | CMOS Linear Sensor |
Focal Length | 60 mm |
Wavelength Range | 180 - 850 nm |
Slit | 25 um |
Resolution | <=1.2 nm |
Optical Design | Symmetrical Czerny-Tuner |
SNR | 330:01:00 |
Dynamic Range | 3450 |
Integration Time | 0.2 ms-1 min |
Stray Light | <.2% |
Wavelength Accuracy | +/- 0.3 nm |
Dynamic Dark Correction | Yes |
Non-Linearity Calibration | Yes |
Wavelength Calibration | Yes |
Trigger Compatible | Yes |
Synchronization Compatible | Yes |
ADC | 16 bits, 2.5 MHz |
Data Transfer Speed: | |
Operating Temp | 0-50 Deg C |
Interface | USB 2.0 UART |
Calibration | NIST Traceable/ ISO17025 Accredited |
Dimensions (mm) HxWxL | 35.4 x 86 x 110 |
Power | 300mA@5VDC (supply voltage 4.75-5.25) |
Storage Temp | -30oC to +70oC |
Operating Temp | 0oC to +50oC |
Relative Humidity | 0% to 90% non-condensing |
Ranges with Input Optics
Optics | ILT960-VIS |
---|---|
RAA4 | 200-850 (Dual Source) |
W/A2 (+MPS2354P2Xd) | 250-850 Dual Source |
R2 | 380-850 (Single Source QTH) |
R3 | 380-850 (Single Source QTH) |
INS50 | 380-850 (300-850 Dual Source) |
INS125 + P6/SMAW | N/A |
W5 | 250-850 (Dual Source) |